BNNHX - SN 60

Product Identification

Product ID:SN 60
MSDS Date:12/12/1988
FSC:3439
NIIN:01-153-2077
MSDS Number: BNNHX

Responsible Party
KESTER SOLDER COMPANY DIV OF LITTON SYSTEMS INC
515 E TOUHY
DES PLAINES, IL 60018-2675
US

Emergency Phone: 312-297-1600

Info Phone: 708-297-1600

Cage: 09185

Contractor
KESTER SOLDER DIVISION OF LITTON SYSTEMS, INC.
DES PLAINES, IL 60018 US

Telephone: 847-297-1600

Cage: 75297

Ingredients

TIN

CAS: 7440-31-5

RTECS: XP7320000

Fraction By Weight: 60%

OSHA PEL 2 MG/M3

ACGIH TLV: 2 MG/M3; 9192


LEAD (SARA III)

CAS: 7439-92-1

RTECS: OF7525000

Fraction By Weight: 39.65%

OSHA PEL 0.05 MG/M3;1910.1025

ACGIH TLV: 0.15 MG/M3;DUST 9192

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


ANTIMONY (SARA III)

CAS: 7440-36-0

RTECS: CC4025000

Fraction By Weight: 0.35%

OSHA PEL 0.5 MG/M3

ACGIH TLV: 0.5 MG SB/M3; 9192

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


BISMUTH

CAS: 7440-69-9

RTECS: EB2600000


CADMIUM (SARA III)

CAS: 7440-43-9

RTECS: EU9800000

OSHA PEL SEE 1910.1027

ACGIH TLV: 0.01 MG/M3 DUST;9394

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS


SILVER (SARA III)

CAS: 7440-22-4

RTECS: VW3500000

OSHA PEL 0.01 MG/M3

ACGIH TLV: 0.1 MG/M3; 9192

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB

Hazards

Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CHRONIC EFFECTS TO KIDNEY,
GASTROINTESTINAL AND NERVOUS SYSTEM. FLUX FUMES MAY CAUSE PULMONARY
IRRITATION AND LUNG DAMAGE.
Explanation of Carcinogenicity:CADMIUM IS A CATERGORY 2B SUSPECT
CARCINOGEN BY IARC-NONE OF THE OTHER METAL ELEMENTS ARE LISTED AS
CARCINOGENS.
Effects of Overexposure:SYMPTOMS FROM INGESTION AND INHALATION INCLUDE
NAUSEA, HEADSCHE, ABDOMINAL DISCOMFORT, JOINT AND MUSCLE PAINS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYE CONTACT: MOLTEN METAL - GET PROMPT MEDICAL ATTENTION.
SKIN CONTACT: MOLTEN METAL - GET PROMPT MEDICAL ATTENTION.
INGESTION IF THOUGHT TO HAVE BEEN OVEREXPOSED, INDIVIDUAL SHOULD BE
TAKEN TO A PHYS ICIAN FOR EVALUATION OF BLOOD LEAD LEVEL AND ANY
GASTROINTESTINAL OR NEUROLOGICAL SYMPTOMS - RENAL FUNCTION SHOULD
ALSO BE EVALUATED.

Fire Fighting

Flash Point:NONE
Extinguishing Media:NONE SPECIFIED BY MANUFACTURER.
Fire Fighting Procedures:SOLDER ALLOYS CONTAINING A SUBSTANTIAL AMOUNT
OF CADMIUM MAY EMIT TOXIC FUMES IN FIRE.
Unusual Fire/Explosion Hazard:FLUX IN CORED SOLDER WIRE OR PASTE SOLDER
MAY BURN IF SOLDERING IS DONE WITH A FLAME.

Handling

Handling and Storage Precautions:WASH HANDS THOROUGHLY WITH SOAP &
WATER BEFORE EATING, DRINKING OR SMOKING AFTER HANDLING SOLDER TO
REMOVE OXIDES OF LEAD.
Other Precautions:USE OF STRONG ACID FLUXES MAY RESULT IN THE EMISSION
OF TOXIC LEAD CHLORIDE FUMES DURING SOLDERING - ALLOYS CONTAINING
CADMIUM MAY EMIT CADMIUM FUMES DURING SOLDERING.

Exposure Controls

Respiratory Protection:METAL FUME AND DUST TYPE - WHEN APPLICABLE.
Ventilation:LOCAL EXHAUST PREFERABLE.
Protective Gloves:NOT REQUIRED.
Eye Protection:SAFETY GLASSES.
Other Protective Equipment:NONE.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING AND BEFORE
EATING, DRINKING OR SMOKING.
Supplemental Safety and Health

Chemical Properties

HCC:N1
Spec Gravity:>7
Solubility in Water:0
Appearance and Odor:GREY METALLIC BAR, WIRE, RIBBON, ETC. WITH NO ODOR.
Percent Volatiles by Volume:0

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:NONE
Hazardous Decomposition Products:NONE

Disposal

Waste Disposal Methods:DISPOSE ACCORDING TO ALL FEDERAL, STATE AND
LOCAL REGULATIONS. MOST PRACTICAL APPROACH IS TO SELL EXCESS SOLDER
MATERIAL TO A METAL RECLAIMER.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.